Micro Spectrophotometer TRMS-605

Micro Spectrophotometer TRMS-605 works as a new type of full-wavelength spectrophotometer. With a mode of USB output or network transfer data, having with an electronic manual. It comes with a Light source as long life pulsed xenon flash lamp. With a pre-installation storage spacing of 32 GB. With a Minimum, a sample volume of the cuvette is 20 μl, with a wavelength range of 190 to 850 nm.

  • Category: Micro Spectrophotometer
  • SKU: TRMS-605
Wavelength Range 190 to 850 nm
Wavelength Accuracy ± 1nm
Wavelength Resolution 2 nm (FWHM at Hg 546 nm)
Repeatability <± 0.5 nm
Light Path 1 mm, 0.05 mm (optical path automatic conversion)
Absorbance Accuracy 1% (0.76 absorbance at 350 nm)
Absorbance Range 0.002 to 300Abs (equivalent to 10mm path length)
sample volume Requirements 0.3 to 2 μl
Cuvette Specifications 1 mm, 2 mm, 5 mm, 10 mm
(optical path)
Min sample volume of the cuvette 20 μl
The minimum height of the cuvette sample 5 mm
Temperature Control 4 to 42 ℃ thermostat adjustable temperature error <± 0.5 ℃
Nucleic Acid measurement range 0.2 to 37500 mg / μl (sa DNA)
Protein measurement range 0.01 to 1120 mg / ml (BSA)
Sample measurement time less than 3s
Sample base material stainless steel and quartz fiber
Light Source long life pulsed xenon flash lamp
Detector 2048(CMOS) element linear silicide CCD array
  • Users can save measurement result data and custom methods directly in spreadsheet mode
  • 32GB of storage space is pre-installed
  • Integrated fiber to prevent fibre breakage due to external force collision, which results in chaotic measurement results
  • There is no need to warm up, start testing whenever you want
  • Built-in Win10 system, built-in 7-inch high-definition display, full touch operation
  • Stainless steel and quartz fiber is used for the platform
  • Using a liquid column to identify abnormal function
  • The built-in Bluetooth and WIFI allow for remote operation and wireless printing of results
  • Two USB ports that can connect to a variety of devices such as mice, keyboards, desktop computers, and so on

Consult Our Specialists

Atomic Absorption Spectrophotometer TRAS-601

Atomic Absorption Spectrophotometer TRAS-601

Wavelength Range : 190 to 900 nm

Wavelength Accuracy : £ ±0.5 nm

Wavelength Repeatability : £ 0.3 nm (single direction)


Atomic Absorption Spectrophotometer TRAS-701

Atomic Absorption Spectrophotometer TRAS-701

Wavelength range  : 190 to 900 nm

Spectral bandwidth : 0.1, 0.2, 0.4, 1.0 and 2.0 nm

Accuracy of the wavelength : ±0.15 nm